Wet cutting machines
Semi-automatic
Cross-cut and automatic feed for precision cuts
Struers RotoPol-31 / RotoForce-4
Grinding and polishing machine
Semi-automatic
Single sample and central pressure
Struers Tegramin-30
Grinding and polishing machine
Semi-automatic
Single sample and central pressure
Struers Lectropol 5
Electrolytic polishing
Electrolytic etching
Deformation-free preparation, e.g. for EBSD analyses
Hitachi ArBlade 5000CTC
Cross-section preparation
Surface polishing
Passive cooling of samples down to -100°C
Cross-section preparation (with Kammrath & Weiss transfer shuttle)
possible under exclusion of oxygen
Struers ProntoPress-20
Hot mounting press
Two-spindle for 30mm and 40mm samples
Photo: Jan Walford
Zeiss Axio Imager.Z2m
Fully motorized
Incident and transmitted light
brightfield, darkfield, DIC, POL
AxioCam HRc high-resolution digital camera
Zeiss Axioplan2
Fully motorized
Incident and transmitted light
brightfield, darkfield, DIC, POL
High-resolution digital camera
AxioCam HRc
Zeiss Axio Zoom.V 16
fully motorized
incident and transmitted light
magnification 3.5 - 110x
Axiocam 512 color high-resolution digital camera
Digital microscope Zeiss Smartzoom 5
Automated digital microscope for routine tasks and error analysis
Magnification 10x to 1011x in relation to 17" monitor
Optical axis on swivel arm with continuously adjustable angle between -45° and +45°
LED coaxial and ring illumination with segmentation
Zeiss Axio Imager.Z2 Vario
Fully motorized
Scanning stage; 300 x 300 mm travel range
Sample height up to 112 mm (without stage 254 mm)
Incident light
Bright field, dark field, POL
Magnification 25x to 2500x
AxioCam 506 color high-resolution digital camera
ZEISS Axioscope 7
Reflected light microscope
Coded reflector unit with brightfield, darkfield and polarization modules
Coded objective nosepiece with EC Epiplan5x, 10x, 20x and 50x objective
Axiocam208 color
Manual single and tile exposure
X/Y cross table and manual Z-axis
ZEN core 2.5 application software
ZEISS Stemi 508
Stereo microscope
Zoom magnification 0.63 - 5x / eyepiece 10x
LED ring illumination
Axiocam208 color
ZEN core 2.5 application software
Photo: Jan Walford
Crossbeam 540/Laser
Gemini-2 FE technology
Combined secondary electron and ion detector
ESB detector for material contrast at acceleration voltages <2kV
4-quadrant backscattered electron detector
STEM detector for transmission electron imaging
Capella Focussed Ion Beam pillars for sample processing on the nanometer scale (FIB)
UV short pulse laser for coarse processing
Kleindiek micromanipulator
ATLAS 3D for high-resolution FIB tomography
EDAX EDX and 3D EBSD analysis
Chemical analyses
Crystallographic analyses (determination of type and orientation) also in volume (3D)
Carl Zeiss Sigma 300VP
Gemini FE technology
Secondary electron detector
4-quadrant AsB backscatter electron detector
VP secondary electron detector with the possibility of simple CL imaging
Variable pressure system for charge-free imaging of non-conductive samples
ATLAS system for large-area, high-resolution imaging
EDAX EDX, EBSD and WDX analysis
Chemical analyses using EDX
Precise determination of even light elements with WDX
Fast EBSD camera with up to 1400 FPS for crystallographic analyses (type and orientation)
Correlative microscopy between light and scanning electron microscopy
Carl Zeiss LEO Gemini 1525
FE scanning electron microscope
Secondary and backscatter electron detectors
EDAX analyzer system with EDX
Holder systems for correlative microscopy
Seifert Sun XRD 3003 fast in-situ X-ray diffractometer:
Standard beam sources (Cu, Co, Mo) with Soller slit system
Dual-circuit goniometer MZ VI E
Minimum step size: 0.0005°
Reproducibility: ± 0.0003°
3 extremely fast XRD detectors Meteor1D
Extremely short readout time of 0.3 ms can be realized
One 40° diffractogram per second possible
Powerful RayfleX software package
High-temperature furnace (DSeTec) for in-situ XRD analyses under the influence of temperature
Temperature range: -50°C up to 1200°C (optional >1800°C)
Maximum temperature gradients: ±15°C/s - 50°C/s* (* with preheated furnace)
Temperature stability for large samples ±2°C
Gas atmospheres: Argon, nitrogen, helium
Autonomous long-term experiments >24 hours by task interpreter are possible
Sample size maximum 100 x 200 mm
Phoenix v|tome|x s
Two X-ray tubes: Nanofocus (180 kV) and microfocus (240 kV)
Digital detector: 2000 x 1500 pixels, pixel size approx. 124 µm
Detail detectability: < 1 µm (nanofocus tube)
Evaluation software Volume Graphics VGStudio MAX 3.0
Xradia Versa 610 X-ray microscope
- CT system with optical post-magnification
- Maximum resolution up to 0.5 µm/voxel
- Transmission X-ray tube: 160 kV, 25 W
- Resolution at a distance
- Supported, sponsored by EU-REACT
- Campus: School of Engineering for Sustainability (ZTN)
FCT Systems gas pressure melt infiltration system
Sample chamber 5L (Æ 190 x H 300 mm^2)
Temperatures up to 2000°C possible, 2 separate heaters (30 kW each)
Temperature control by means of WRe-TC or ratio pyrometer
lid cooling for gradient adjustment/directional solidification of MMC components
Hydraulic immersion system
Vacuum tank, Æ 0.5 x 1 m^2
Vacuum approx. 5x10^-4 bar/100 bar argon
Working pressure 1 to +100 bar
Planetary mill PULVERISETTE 5 classic line
Four grinding stations
Grinding bowl sizes: 80, 250, 500 ml
Grinding ball diameter: 0.5 - 40 mm
Final fineness < 1 µm
Main disk speed: 50 - 400 rpm
Dry/wet grinding process possible
Grinding under protective gas possible
Programmable grinding and pause times as well as grinding cycles in reverse operation possible
Büchi mini spray dryer B-290
Including dehumidifier B-296 and inert loop B-295
Staff can work with organic solvents
Evaporator capacity: 1.0 l/hr H2O, higher for organic solvents
Air flow rate: max. 35 m³/h
Max. Max. inlet temperature: 220 °C
Heating capacity: 2300 W
Control accuracy: ± 3 °C
Spray gas compressed air or nitrogen: 200-1000 l/hr, 5-8 bar
Nozzle diameter: 0.7 mm standard, 1.4 and 2.0 mm available as accessories
Nozzle cap: 1.4 mm and 1.5 mm diameter
Average dwell time: 1.0-1.5 s
Possible field (of) particle diameter: 1-25 μm
RS-232 interface for output of all parameters
Linn VMK-S80
Furnace chamber dimensions:
180 x 210 x 140 mm³
Tmax: 1050°C
Special features: TNV, inert gas atmosphere, vacuum
Kilns & Furnaces CU4
Furnace chamber dimensions: 200 x 228 x 250 mm³
Tmax: 1300°C
Degussa LKs 15/8/25
Furnace chamber dimensions: 160 x 300 x 80 mm³
Tmax: 1350°C
Nabertherm N41
Furnace chamber dimensions 350 x 500 x 250 mm³
Tmax: 1150°
Heraeus MR170
Furnace chamber dimensions: 170 x 250 x 90 mm³
Tmax: 1000°C
Gero HT-RH 70-300/16
High-temperature tube furnace
Tmax: 1600°C
Protective gas atmosphere
Optimol SRV3
Vibration and friction wear testing machine
Normal force: 20 - 2000 N
Temperature: RT - 290°C
Vibration: 0.1 - 4 mm
Frequency: 1 - 511 Hz
Dry and lubricated examinations possible
New battery research laboratories in the research building "School of Engineering for Sustainability (ZTN)" at Aalen University of Applied Sciences.
Glovebox systems
Operation under argon atmosphere in negative or positive pressure
Oxygen/water content < 1 ppm
Multi-chamber gloveboxes for different tasks:
Glovebox for cell assembly (Coin, Swagelok, Pouch, PAT)
Glovebox for powder-based solid batteries with flange-mounted high-temperature furnace (Ar atmosphere, Tmax = 1600°C) and H2S sensors for processing sulphide materials
Glovebox for metallographic preparation in an inert gas atmosphere
Glovebox for microscopic analysis in an inert gas atmosphere
Glovebox for cell opening of high-capacity cells
Further gloveboxes for inert gas analysis (RAMAN and LIBS) in procurement
Manufacturing processes for electrode and cell production on a laboratory scale
Various mixers for the production of electrode pastes (laboratory stirrer, planetary centrifugal mixer)
Doctor blade coater with heatable vacuum plate for electrode coating
Several laboratory calenders for electrode compaction (some heatable up to 200 °C)
Punching and cutting tool for punching out electrodes
Crimper for (dis)assembling button cells (format: CR2032)
Vacuum device for assembling pouch cells
Battery test systems with (safety) climate chambers
> 100 independent test channels (with channel-specific thermocouples) with
62 channels: max. 3 A / +/-6 V (CTS Lab, BaSyTec)
40 channels: max. 5 A / 0-6 V (CTS Standard, BaSyTec)
6 channels: max. 50 A / 0-4.5 V (XCTS, BaSyTec)
8 measuring channels for the connection of load cells for chemo-mechanical cell tests
9 measuring channels for specific electrochemical analyses (e.g. EIS, GITT)
5 channels: max. 400 mA / +/- 10V / 10 µHz - 1 MHz (VSP, BioLogic)
3 channels: max. 500 mA / +/- 12V / 10 µHz - 7 MHz (VSP-300, BioLogic)
1 channel: max. 100 mA / +/- 21V / 10 µHz - 250 kHz (Vertex.One.EIS, Ivium)
Multiple climate chambers for temperature control (-10°C < T < 100°C)
Multiple safety climate chambers (Hazad Level 5) (-40°C < T < 180°C)
Specific test cells and tensioning frames for variable superimposition of mechanical and electrochemical loads
Manufacturing processes for the production of powder-based solid-state batteries on a laboratory scale
Various ball mills for mixing, grinding and homogenizing the powders
Cold isostatic and uniaxial presses, specific test cells for compacting and compressive stressing
High-temperature furnace combined with glovebox (Ar atmosphere, Tmax = 1600°C) for the synthesis and sintering of air-sensitive materials such as sulphide solid electrolytes
Several furnaces for heat treatment (Tmax = 1300°C, partly under inert gas)
Material and microstructure analyses under inert gas atmosphere
Light microscopic analyses integrated in glovebox (stereomicroscope, inverse reflected light microscope; up to 1000x magnification, accordingly a 100x objective)
Sputtering system (Au, Au/Pd, C) integrated in glovebox
Transfer modules for sample transfer to (i) scanning electron microscope with FIB unit, EDX/WDX and EBSD XRD and (ii) XRD incl. climate chamber with heating function up to 1050°C and operando measuring cell
Confocal Raman microscope and laser-induced plasma spectroscope (LIBS) in procurement
LOT / Quantum Design vibrating magnetometer with microscope unit
QD-PPMS-9 multifunctional magnetometer
Measurements in the temperature range 1.9 K to 1000 K and field range -9 T .... 9 T
Measurements of the full hysteresis curve, kink point measurements, reversibility measurements, relaxation measurements Determination of the magnetic parameters µ0HC, JR, (BH)max DC/AC measurements
Torque functions
Microscope function: AFM/MFM (atomic force/magnetic force unit) for visualizing the scattered fields of domain structures, SHP (scanning Hall probe unit) for quantitative determination of local scattered fields, in each case as a function of field and temperature
Max. Heat compensation 1000 W
Magnet-Physics Dr. Steingroever GmbH Permagraph C-300
Computer-controlled Permagraph C-300
Measurements in the temperature range RT to 200°C
Measurements of the hysteresis curve in the 2nd quadrant up to - 2 Tesla
Determination of the magnetic parameters µ0HC, JR, (BH)max
FeCo pole pieces
Magnetometry: length/width min. 0.5 cm x 0.5 cm, max. 2 cm x 1.5 cm, height > 1 mm
Magnet-Physik Dr. Steingroever GmbH IM-K Impulse magnetizer
Pulse magnetizer
Magnetizing coil 52.0 mm (aperture) x 60 mm (active length)
Magnetizing with aperiodically damped discharge
Variable field pulse up to a maximum of 7.2 Tesla for complete saturation of the magnets
Helmholtz coil
Moment coil type MS 150 for measuring the magnetic moment and dipole moment of permanent magnets
Free aperture 140 mm
Dimensions for 1% accuracy: max. magnet height 50 mm, max. diameter 70 mm
Dr. Brockhaus Metrology GmbH & Co. KG MPG 200D
Determination of soft magnetic parameters in AC and DC according to IEC 60404-ff, repeatability 0.1%
Alternating field measurements between 1 Hz and 100 kHz
Sine, free waveforms, bias measurements, new curve
Sample geometries: Epstein strips, plate and ring samples
Maximum current 40 A, maximum voltage 100 V
Measurements under temperature possible (< 300°C)
Keysight E4990A impedance analyzer
20 Hz to 20 MHz
16047E Test fixture for components with axial connections
Measurement parameters: |Z|, |Y|, θ, R, X, G, B, L, C, D, Q, Z (complex)
Basic accuracy of the impedance measurement: ± 0.08 %
Number of measuring points: 2 to 1,601
Measurements under bias
Magnetic field scanner MMS-1A-RS
3D measurement of magnetic fields of hard magnets
Measuring range: 1.5 T
Measuring accuracy of the magnetic field: 0.1%
Measurement possible in 4 axes (X, Y, Z and rotation)
Resolution: 2 µm (X, Y, Z), 0.02° (rotation)
Measuring volume: 135 x 135 x 135 mm
TrupPrint1000
Selective laser melting for complex metallic components
Multi-laser version with 2 x 200 W fiber laser
Installation space: diameter 100 mm x 100 mm height (small powder quantities)
Glovebox for processing even reactive materials
Material and process development in cooperation, cooperative venture, partnership, collaboration with the LaserApplikationsZentrum (LAZ)
Lithoz CeraFab 7500-45
Lithography-based additive manufacturing
Production of resin-bonded ceramic (or metal) components with subsequent debinding and sintering
DLP projector with 40 µm resolution
Build platform 45 x 75 mm²
Material and slip winding
KUKA KR 16 S robot - adhesive dispenser
Installation position: Floor
Number of axes: 6
Repeat accuracy: ± 0.05 mm
Nominal load capacity of the central hand: 16 kg
Additional load: 30 kg
Reach: 1.6 m
ProtoMAX waterjet cutting system
Processing area: 304 x 304 mm²
Processing height: < 25 mm
Blasting medium: garnet sand
Feed rate: < 2.5 m/min
Working pressure: 2,000 bar
Positioning accuracy: ± 0.127 mm
Repeat accuracy: ± 0.076 mm
DYNA-MESS V2H 35 HCF - Vibration testing machine
Servo-hydraulic 2-pillars vertical testing machine
Force and displacement controlled examination
Test force: < 25 kN for dynamic load with < 10 kN preload force
Test travel: ≤ 100 mm (± 50 mm around the center position)
Frequency: ≤ 100 Hz
Integrated temperature sensor -20 to 200 °C
Mechanical sample clamping
Memmert CTC256 - Environmental test chamber
Test chamber dimensions: 640 x 670 x 597 mm³
Temperature range:
Without humidity: -42 °C to +190 °C
With humidity: +10 °C to +95 °C
Temperature measurement using 2PT100 sensors DIN class A
Active humidification and dehumidification from 10-98 % relative humidity
Humidification by means of hot steam generation from distilled water